- Product name
- Mantis
- Type
- Fixed / static
- Material
- Steel
- Crash rating
- IWA 14
- PAS 68
- Aboveground height (mm)
- 1080–1100mm (excl cover)
- 1130mm (incl standard cover)
- Belowground height (mm)
- Foundation depth: 250–300mm
- Aboveground diameter / width (mm)
- 190mm (excl cover)
- 196mm (incl standard cover)
Heald’s Mantis range is a static security bollard system made from hot dip galvanised steel, designed for high-impact vehicle mitigation with shallow foundation depths of 250–300mm. Crash-tested as single units and in arrays to PAS 68 and IWA-14-1 standards at 64kph and 80kph, they combine high security with rapid installation and a choice of stainless steel covers.
Static security bollard system for vehicle impact protection with shallow foundations
Crash-tested to PAS 68 and IWA-14-1 standards at 64 and 80kph
Hot dip galvanised steel base for corrosion resistance
Zero penetration and zero dispersion in crash tests
Installation in under an hour with no pre-cast pit or additional rebar
Stainless steel covers in standard or bespoke designs and colours
Compatible for use in flexible arrays with other security products
Applications
Perimeter security for commercial and public buildings
Urban streetscapes requiring discreet vehicle mitigation
Sites with modern architectural requirements
Critical infrastructure protection
Entrances to pedestrian zones
Transport hubs and event venues
Dimensions
Height: 1080–1100mm (excluding cover) | 1130mm (including standard cover)
Width: 190mm (excluding cover) | 196mm (including standard cover)
Foundation depth: 250–300mm
Performance
PAS 68:2013 Fixed Bollard V/7500[N2]/64/90:0.0/0.0
IWA14-1-V/7200[N3C]/80/90:7.5 (single bollard)
IWA14-1:2013 Bollard V/7200[N2A]/80/90:3.5 (array of 3)
Zero penetration and zero dispersion in crash tests
Bollards remain protective after impact
Materials
Hot dip galvanised steel
Stainless steel covers
Colours
Can be painted any colour
Finish
Galvanised, primed and painted
Options and variations
Standard and bespoke stainless steel cover designs
Available as single units or in arrays
Installation
Excavation depth: 250–300mm
No pre-cast pit or additional rebar required
Installation in under an hour
Accreditations
PAS 68 tested
IWA-14-1 tested