- Product name
- Stronguard™ RCS
- System type
- Steel palisade systems
- Product accreditation
- IWA 14
- NPSA / CPNI approved
- PAS 68
- Secured by Design
- Fence height
- 1.8, 2.4, 3.0m
- Wire / bar diameter
- 3, 3.5, 4mm pale thickness
- Post centres
- 2.75m
- Post sections
- 120 x 80 RHS
The Stronguard™ RCS retrofit crash system offers super-strong and durable ultimate security palisade fencing. It can be supplied new or retrofitted on site.
Designed for the security of top assets which form part of the critical national infrastructure, Stronguard™ RCS provides unrivaled attack delay against saws, cutting, hammers, jacks, levers, power tools and hand tools.
The hostile vehicle mitigation perimeter is available at two levels and offers some of the highest levels of security for even the most sensitive sites.
Features
PAS 68 certified
Secured by Design
No visible fixings
‘D’ profile
Fix from the rear with a high load anchor
Accommodates slopes up to 30° without requiring alterations on site
Galvanised to British Standard EN ISO 1461:2009
Specifications
Product |
Height (m) |
Pale type |
Security rating |
|---|---|---|---|
StronGuard RCS |
1.8-3.0 |
D |
CPNI BEH |
StronGuard SL1 RCS |
1.8-3.0 |
W |
LPS 1175 A1 (SR1) |
StronGuard SL2 RCS |
2.4-3.0 |
W |
LPS 1175 B3 (SR2) |
Standard post centres: 2.75m
Standard foundations: 450mm sq hole (inters) and 600mm sq hole (corners/ends)
Impact classification
Product |
Vehicle weight (kg) |
Vehicle type |
Test speed (kph) |
Impact angle (°C) |
Penetration (m) |
Dispersion of major debris (m) |
|---|---|---|---|---|---|---|
StronGuard™RCS 25: |
2500 |
N1G |
48 |
90 |
0 |
0 |
StronGuard™RCS 75: |
7500 |
N2 |
48 |
90 |
3.5 |
0 |
Options
Powder coating in a range of RAL colours
Barbed wire toppings
Razor wire toppings
Electrified fence
PIDs and PIDs systems
Applications
Airports
Military
Rail
Utility
Petrochemical plants
All sites that demand maximum security
Accreditation
Barkers Stronguard™ RCS 25 and RCS 75 is the first palisade fence system to gain PAS 68 accreditation.
PAS 68: 2010: 2500 (N1G)/48/90 0.0
PAS 68: 2010:7500 (N2)/48/90 3.5/ 0.3
Services
Can be installed by Barkers approved installers.